ELECTRICAL INSPECTIONS
All services must be a minimum of 100 AMP.
60 AMP services will no longer be allowed. What size of service do
I have????? Click here
to see.
Correct wire size is a must!
Temporary poles must be a minimum of 8 inch diameter
pole. Meter can will be 6ft off of ground, weatherhead
12 ft.
All services must be grounded with an APPROVED
ground rod. Grounding to waterline will NOT be allowed.
Service must be securely attached to pole or
structure.
On new construction all bathrooms, kitchens
and garages must have GFI protection.
Electrical cable must be buried in schedule
80 gray electrical conduit, or direct burial cable.
All inspections are $19.00 effective April 1, 2010.